Cooling unit Wall / Door
For wall or door mounting
300W - 6000W | IP54
Cooling units for wall or door mounting with cooling capacity from 300 to 6000 W for industrial enclosures.
The unit is available in painted steel sheet RAL7035 or in stainless steel AISI304L and acid-resistant AISI316L (on request) and is equipped with a hot-pipe for condensation evaporation, a washable air filter and the possibility of UL certification.
Specification
| Article: | Cooling unit Wall / Door |
|---|---|
| Category: | Cooling Units |
| Brand: | DKC |
| Protection class: | IP54 |
| Voltage: | 115V | 230V | 380/480V | 400/480V |
| Effect: | 300W - 6000W |
| Operating temperature: | 20°C - 50°C | 20°C - 55°C (UL) |
| Housing material: | Steel sheet | Stainless steel AISI304L | Acid-resistant AISISIL316L (on request) |
| Color: | RAL7035 (steel sheet) |
Do you need a price & more information?

Product description
Cooling units for wall or door mounting, with power from 300W to 6000W.
With housing in painted steel sheet RAL7035 or in stainless steel AISI304L and in acid-resistant AISI316L (on request).
- The cooling units are also available with UL certification.
Base:
- 1st PLUG-IN connector for power supply
- Visual alarm for minimum/maximum temperature
- Modifiable intervention set
- 2 PLUG-IN connectors for power supply
- Control with alarm for overtemperature
- Remote ON/OFF (door contact switch)
- RS485 serial interface for remote control (ordered separately)
Other:
- Foamed polyurethane gasket on the back of the unit.
- Built-in "hot-pipe" loop in the condensate tray that evaporates the condensate water.
- External washable air filter.
- Textured coated in RAL7035.
- Other RAL colors are available.
- Visual alarm on TOP version.
- RS485 serial protocol is available on request.
- Other power supply voltage possible.
Drawing
Article number
| Art.No | Name | Version | Capacity | Input voltage AC | Operating temperature: | Width mm | Height mm | Depth mm | Protection class | Color / Material (housing) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| R5CND03021LB | Cooling Units | Base | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| RICND03021LB | Cooling unit | INOX | Base | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | AISI304L | |
| RIULK03021L | Cooling unit | INOX | Base UL | 300W | 230V | 20°C-55°C | 280 | 500 | 180 | IP54 | AISI304L | |
| R5CND03021LT | Cooling Units | Top | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| RICND03021LT | Cooling unit | INOX | Top | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | AISI304L | |
| R5ULK03021L | Cooling Units | Top UL | 300W | 230V | 20°C-55°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| R5CND05021LB | Cooling Units | Base | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND05021LB | Cooling unit | INOX | Base | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| RIULK05011L | Cooling unit | INOX | Base UL | 500W | 115V | 20°C-55°C | 280 | 595 | 220 | IP54 | AISI304L | |
| RIULK05021L | Cooling unit | INOX | Base UL | 500W | 230V | 20°C-55°C | 280 | 595 | 220 | IP54 | AISI304L | |
| R5CND05021LT | Cooling Units | Top | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND05021LT | Cooling unit | INOX | Top | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| R5ULK05011L | Cooling Units | Top UL | 500W | 115V | 20°C-55°C | 280 | 595 | 220 | IP54 | RAL7035 | |
| R5ULK05021L | Cooling Units | Top UL | 500W | 230V | 20°C-55°C | 280 | 595 | 220 | IP54 | RAL7035 | |
| R5CND08021LB | Cooling Units | Base | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND08021LB | Cooling unit | INOX | Base | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| RIULK08011L | Cooling unit | INOX | Base UL | 800W | 115V | 20°C-55°C | 280 | 630 | 270 | IP54 | AISI304L | |
| RIULK08021L | Cooling unit | INOX | Base UL | 800W | 230V | 20°C-55°C | 280 | 630 | 270 | IP54 | AISI304L | |
| R5CND08021LT | Cooling Units | Top | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND08021LT | Cooling unit | INOX | Top | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| R5ULK08011L | Cooling Units | Top UL | 800W | 115V | 20°C-55°C | 280 | 630 | 270 | IP54 | RAL7035 | |
| R5ULK08021L | Cooling Units | Top UL | 800W | 230V | 20°C-55°C | 280 | 630 | 270 | IP54 | RAL7035 | |
| R5CND10021LB | Cooling Units | Base | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND10021LB | Cooling unit | INOX | Base | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK10011L | Cooling unit | INOX | Base UL | 1000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| RIULK10021L | Cooling unit | INOX | Base UL | 1000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND10021LT | Cooling Units | Top | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND10021LT | Cooling unit | INOX | Top | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK10011L | Cooling Units | Top UL | 1000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| R5ULK10021L | Cooling Units | Top UL | 1000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND15021LB | Cooling Units | Base | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND15021LT | Cooling unit | INOX | Base | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK15011L | Cooling unit | INOX | Base UL | 1500W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| RIULK15021L | Cooling unit | INOX | Base UL | 1500W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND15021LT | Cooling Units | Top | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND15021LB | Cooling unit | INOX | Top | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK15011L | Cooling Units | Top UL | 1500W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| R5ULK15021L | Cooling Units | Top UL | 1500W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND20021LB | Cooling Units | Base | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND20021LB | Cooling unit | INOX | Base | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK2BF11L | Cooling unit | INOX | Base UL | 2000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| R5ULK2BF21L | Cooling Units | Base UL | 2000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND20021LT | Cooling Units | Top | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND20021LT | Cooling unit | INOX | Top | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK2BF11L | Cooling Units | Top UL | 2000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| RIULK2BF21L | Cooling unit | INOX | Top UL | 2000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND30043LB | Cooling Units | Base | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND30043LB | Cooling unit | INOX | Base | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5CND30043LT | Cooling Units | Top | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LT | Cooling unit | INOX | Top | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5ULK30043L | Cooling Units | Top UL | 3000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RIULK30043L | Cooling unit | INOX | Top UL | 3000W | 400/460V 3-phase | 20°C-55°C | 500 | 110 | 345 | IP54 | AISI304L | |
| R5CND40043LB | Cooling Units | Base | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LB | Cooling unit | INOX | Base | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5CND40043LT | Cooling Units | Top | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LT | Cooling unit | INOX | Top | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5ULK40043L | Cooling Units | Top UL | 4000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RIULK40043L | Cooling unit | INOX | Top UL | 4000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5KLM60043LT | Cooling Units | Top | 6000W | 400/460V 3-phase | 20°C-50°C | 550 | 1400 | 400 | IP54 | RAL7035 |
Accessories
Video
Document
You may also need...
Cable duct slotted halogen-free in U43X
Stainless steel floor standing cabinet | Door & Back Panel | AISI304L & AISI316L | IP55
Floor standing cabinet | Door & Rear panel | IP55
Slim design, high performance for control and automation cabinets
Output current 3.4 to 40A | Efficiency up to 93% | AC input voltage | Screw terminal
Panel-mounted power meters with MID certification for billing and advanced power quality analysis
Do you need help choosing the right solution?
Choosing components is often about more than dimensions and threads.
Material choice, seals, IP class and environmental requirements affect both function and lifespan.
If you are unsure, we are happy to help you ensure that the solution works in your application.