Cooling Units
For wall or door mounting
300W - 6000W | IP54
Cooling Units
For wall or door mounting
300W - 6000W | IP54
Specification
| Article: | Cooling Units |
|---|---|
| Category: | Cooling Units |
| Brand: | DKC |
| Protection class: | IP54 |
| Voltage: | 115V | 230V | 380/480V | 400/480V |
| Effect: | 300W - 6000W |
| Operating temperature: | 20°C - 50°C | 20°C - 55°C (UL) |
| Housing material: | Steel sheet | Stainless steel AISI304L | Acid-resistant AISISIL316L (on request) |
| Color: | RAL7035 (steel sheet) |
Do you need a price & more information?
Rating: 5/5

Product description
Cooling units for wall or door mounting, with power from 300W to 6000W.
With housing in painted steel sheet RAL7035 or in stainless steel AISI304L and in acid-resistant AISI316L (on request).
- The cooling units are also available with UL certification.
Base:
- 1st PLUG-IN connector for power supply
- Visual alarm for minimum/maximum temperature
- Modifiable intervention set
Top:
- 2 PLUG-IN connectors for power supply
- Control with alarm for overtemperature
- Remote ON/OFF (door contact switch)
- RS485 serial interface for remote control (ordered separately)
Other:
- Foamed polyurethane gasket on the back of the unit.
- Built-in "hot-pipe" loop in the condensate tray that evaporates the condensate water.
- External washable air filter.
- Textured coated in RAL7035.
- Other RAL colors are available.
- Visual alarm on TOP version.
- RS485 serial protocol is available on request.
- Other power supply voltage possible.
Drawing
Article number
| Art.No | Name | Version | Capacity | Input voltage AC | Operating temperature: | Width mm | Height mm | Depth mm | Protection class | Color / Material (housing) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| R5CND03021LB | Cooling Units | Base | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| RICND03021LB | Cooling unit | INOX | Base | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | AISI304L | |
| RIULK03021L | Cooling unit | INOX | Base UL | 300W | 230V | 20°C-55°C | 280 | 500 | 180 | IP54 | AISI304L | |
| R5CND03021LT | Cooling Units | Top | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| RICND03021LT | Cooling unit | INOX | Top | 300W | 230V | 20°C-50°C | 280 | 500 | 180 | IP54 | AISI304L | |
| R5ULK03021L | Cooling Units | Top UL | 300W | 230V | 20°C-55°C | 280 | 500 | 180 | IP54 | RAL7035 | |
| R5CND05021LB | Cooling Units | Base | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND05021LB | Cooling unit | INOX | Base | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| RIULK05011L | Cooling unit | INOX | Base UL | 500W | 115V | 20°C-55°C | 280 | 595 | 220 | IP54 | AISI304L | |
| RIULK05021L | Cooling unit | INOX | Base UL | 500W | 230V | 20°C-55°C | 280 | 595 | 220 | IP54 | AISI304L | |
| R5CND05021LT | Cooling Units | Top | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND05021LT | Cooling unit | INOX | Top | 500W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| R5ULK05011L | Cooling Units | Top UL | 500W | 115V | 20°C-55°C | 280 | 595 | 220 | IP54 | RAL7035 | |
| R5ULK05021L | Cooling Units | Top UL | 500W | 230V | 20°C-55°C | 280 | 595 | 220 | IP54 | RAL7035 | |
| R5CND08021LB | Cooling Units | Base | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND08021LB | Cooling unit | INOX | Base | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| RIULK08011L | Cooling unit | INOX | Base UL | 800W | 115V | 20°C-55°C | 280 | 630 | 270 | IP54 | AISI304L | |
| RIULK08021L | Cooling unit | INOX | Base UL | 800W | 230V | 20°C-55°C | 280 | 630 | 270 | IP54 | AISI304L | |
| R5CND08021LT | Cooling Units | Top | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | RAL7035 | |
| RICND08021LT | Cooling unit | INOX | Top | 800W | 230V | 20°C-50°C | 310 | 630 | 220 | IP54 | AISI304L | |
| R5ULK08011L | Cooling Units | Top UL | 800W | 115V | 20°C-55°C | 280 | 630 | 270 | IP54 | RAL7035 | |
| R5ULK08021L | Cooling Units | Top UL | 800W | 230V | 20°C-55°C | 280 | 630 | 270 | IP54 | RAL7035 | |
| R5CND10021LB | Cooling Units | Base | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND10021LB | Cooling unit | INOX | Base | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK10011L | Cooling unit | INOX | Base UL | 1000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| RIULK10021L | Cooling unit | INOX | Base UL | 1000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND10021LT | Cooling Units | Top | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND10021LT | Cooling unit | INOX | Top | 1000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK10011L | Cooling Units | Top UL | 1000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| R5ULK10021L | Cooling Units | Top UL | 1000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND15021LB | Cooling Units | Base | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND15021LT | Cooling unit | INOX | Base | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK15011L | Cooling unit | INOX | Base UL | 1500W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| RIULK15021L | Cooling unit | INOX | Base UL | 1500W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND15021LT | Cooling Units | Top | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND15021LB | Cooling unit | INOX | Top | 1500W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK15011L | Cooling Units | Top UL | 1500W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| R5ULK15021L | Cooling Units | Top UL | 1500W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND20021LB | Cooling Units | Base | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND20021LB | Cooling unit | INOX | Base | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| RIULK2BF11L | Cooling unit | INOX | Base UL | 2000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | AISI304L | |
| R5ULK2BF21L | Cooling Units | Base UL | 2000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| R5CND20021LT | Cooling Units | Top | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | RAL7035 | |
| RICND20021LT | Cooling unit | INOX | Top | 2000W | 230V | 20°C-50°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5ULK2BF11L | Cooling Units | Top UL | 2000W | 115V | 20°C-55°C | 400 | 1050 | 237 | IP54 | RAL7035 | |
| RIULK2BF21L | Cooling unit | INOX | Top UL | 2000W | 230V | 20°C-55°C | 400 | 950 | 237 | IP54 | AISI304L | |
| R5CND30043LB | Cooling Units | Base | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND30043LB | Cooling unit | INOX | Base | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5CND30043LT | Cooling Units | Top | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LT | Cooling unit | INOX | Top | 3000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5ULK30043L | Cooling Units | Top UL | 3000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RIULK30043L | Cooling unit | INOX | Top UL | 3000W | 400/460V 3-phase | 20°C-55°C | 500 | 110 | 345 | IP54 | AISI304L | |
| R5CND40043LB | Cooling Units | Base | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LB | Cooling unit | INOX | Base | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5CND40043LT | Cooling Units | Top | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RICND40043LT | Cooling unit | INOX | Top | 4000W | 400/440V 3-phase | 20°C-50°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5ULK40043L | Cooling Units | Top UL | 4000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | RAL7035 | |
| RIULK40043L | Cooling unit | INOX | Top UL | 4000W | 400/460V 3-phase | 20°C-55°C | 500 | 1100 | 345 | IP54 | AISI304L | |
| R5KLM60043LT | Cooling Units | Top | 6000W | 400/460V 3-phase | 20°C-50°C | 550 | 1400 | 400 | IP54 | RAL7035 |
Accessories
Video
Document
You might also like…
Free blow 15 m³/h - 930 m³/h
Wall cabinet / Floor cabinet in Stainless steel | Fully welded | AISI304L | IP55
Floor standing cabinet | With welded ends | IP66
For wall or door mounting
500W - 4000W | IP54
Stainless steel wall cabinet with integrated rain canopy | AISI304L & AISI316L | IP66