Nödstoppsdon – För industri och automation

Ø16.2–30.5 mm |Twist and pull reset | Up to IP69K

Emergency stop devices from Schlegel for machinery, cabinet enclosures and industrial control systems. The range includes multiple mounting sizes, reset functions and contactless solutions. With protection ratings from IP65 to IP69K, depending on the design, the products are suitable for various industrial applications and safety requirements.

Specification

schlegel_logo
Article:Emergency stop button
Category:Emergency Stops
Brand:Schlegel
Function:Locking emergency stop function
Hole punching: Ø16.2 | Ø22.3 | Ø30.5 mm
Alternative hole locations:23 × 23 | 24 × 24 | 26 × 26 mm
Recovery:Rotation or drag reset
Degree of protection:IP65–IP69K depending on the article
Contact function:Contact function
Security channels:One- or two-channel versions
Contact block:Standard contact blocks and compatible safety solutions
Standards:EN ISO 13850, EN 60947-5-5, EN 60947-5-1
Approvals:Depending on the article
Montage:Panel mounting

PRODUCT OVERVIEW

Emergency stop devices from Schlegel are used to stop dangerous machine functions in an emergency situation. The range includes different sizes, mounting options, and reset functions for machines, cabinet enclosures, and industrial control systems.

Schlegel offers emergency stop devices with openings from Ø16.2 to Ø30.5 mm as well as several square mounting sizes. Depending on the design, protection ratings from IP65 up to IP69K are available. The products can be combined with compatible safety-related contact blocks.

Several mounting dimensions and designs

Schlegel’s emergency stop devices are available for various types of industrial control panels. The range includes both compact solutions and larger emergency stop devices for clear and easily accessible operation.

Available hole sizes include, among others:

  • Ø16.2 mm for compact control panels.
  • Ø22.3 mm for common industrial panel mounting.
  • Ø30.5 mm for larger mounting configurations.
  • Square mounting dimensions of 23 × 23, 24 × 24 and 26 × 26 mm.

The choice of emergency stop devices depends on the panel design, available space, and the safety requirements of the machine.

Always check the clearance, panel thickness and mounting depth for the specific application.

Twist and pull adjustment

The emergency stop button from Schlegel has a locking operation. When the operator presses the emergency stop button, it remains in the activated position until it is reset manually.

Depending on the model, the reset process is done by twisting or by pulling the button out.

In the case of rotation restoration, there are versions that can be rotated in both directions. Other models have special restoration functions.

The reset releases the emergency stop button, but it does not automatically restart the machine. The machine's control system must handle the restart according to the safety function requirements.

Safety-related contact blocks

The emergency stop socket can be combined with compatible contact blocks for safety-related control circuits.

Schlegel offers contact blocks with forced opening function according to EN 60947-5-1, Annex K. This means that the mechanical operation opens normally closed contacts through a defined mechanical movement.

Depending on the configuration, there are solutions for one or two security channels.

When choosing a product, you need to check the following:

  • The contact block's compatibility with the emergency stop device.
  • The number of normally closed contacts (NC).
  • Electrical load and connection method.
  • Requirements for the security circuit architecture.
  • Any requirements for monitoring the assembly of contact blocks.

An emergency stop head is not automatically a complete safety feature. The finished installation must be designed according to the machine’s risk assessment.

Protection level for demanding industrial environments

Schlegel offers emergency stop devices with protection ratings from IP65 up to IP69K, depending on the article.

IP65 means dustproof performance and protection against water jets. IP67 also includes protection in case of temporary immersion under defined testing conditions.

IP69K is used for applications that have been tested against high-pressure and high-temperature flushing.

The actual level of protection depends on the product's design and mounting conditions. Always check the manufacturer's data sheet.

Also note that the front side and the electrical connections behind the panel may have different protection requirements.

Clear maneuvering and recovery

Schlegel's emergency stop devices are designed for clear identification and operation in an emergency situation.

The range includes models with visible status indication and various mechanical designs, allowing the machine builder to choose a solution based on availability, location, and the application environment.

Some versions have special protection against inadvertent operation. Such accessories must not impair the visibility or accessibility of the emergency stop.

Standards and machine safety

The emergency stop function must be designed in accordance with the machine’s risk assessment and relevant safety standards.

For Schlegel's emergency stop device, the following standards are particularly relevant:

  • EN ISO 13850: Principles for the design of emergency stop functions.
  • EN 60947-5-5: Requirements for electric emergency stop devices with mechanical locking function.
  • EN 60947-5-1: Requirements for electromechanical control circuits and forced-opening contacts.

Schlegel offers products with TÜV and UL approvals. Exact approvals and applicable standards should be checked for the selected item.

The emergency stop is a supplementary safety feature. It does not replace other protective measures required by the risk assessment.

Common areas of use

The Schlegel emergency stop device is used in machinery and industrial plants where dangerous functions need to be stopped in an emergency situation.

Examples of applications:

  • Industrial production machinery.
  • Automated production lines.
  • Operator panels and control stations.
  • Equipment cabinets and machine enclosures.
  • Machines in the OEM industry.

Request a quote for Nödstoppsdon – För industri och automation

Art.NoCommentUnitPack QtyPDFCountOffer
Emergency stop buttonPlease specify the desired hole size, reset function, contact performance and number.st1

Related Products

Need Help Finding the Right Solution?

Our product specialists will help you choose the right solution for your application. Contact us for technical advice, product selection or a quote.

C-Pro-logo
Fill in the form and we will contact you for more information.

When you submit a form, we process your personal data in accordance with our Privacy Policy.
There you can read more about how we work with data protection and GDPR.