CONTROL COMPONENTS
Industrial networks for control devices
Modular bus systems for flexible connection to industrial control systems.
Industrial networks from Schlegel simplify the connection of push buttons, signal lights and other control devices to the machine's control system. With the modular bus system MBS, you can reduce the amount of wiring and connect up to 128 control points.
What are industrial control networks for control devices?
Schlegel’s modular bus system MBS connects pushbuttons, signal lights and rotary switches to industrial control systems via a common communication interface.
The system consists of a network-specific base module and expansion modules for more inputs and outputs. This reduces the need for separate cables between the control panel and the control system.
Therefore, use Schlegel MBS
- Less wiring in machines and equipment cabinets.
- Easier installation of larger control panels.
- Flexible expansion with more control points.
- Support for several industrial network protocols.
- Possibility to change the base module when changing the bus system.
Common areas of use
Schlegel's MBS is suitable for industrial installations where several control units need to be connected to a common control system.
- Operator panels and control panels.
- Machines with many push buttons and indicator lights.
- Production lines that require flexible expansion.
- System with RFID-based identification.
- OEM machines and custom-made automation.
Do you need help choosing the right network solution?
This is how MBS works
MBS collects signals from several control units and transmits them to the machine's control system via an industrial network.
The system consists of a base module and expansion modules that can be expanded as needed.

The base module – the connection to the network
The base module communicates with the machine’s control system. You choose it according to the network protocol used by the customer, such as PROFINET, EtherCAT, or EtherNet/IP.When switching to another bus system, the base module can be replaced while compatible expansion modules are retained.
Expansion modules – connect more control units
The expansion modules connect push buttons, signal lights and other functions to the MBS system.One base module can be combined with up to 15 expansion modules. In total, the system can handle up to 128 control points.
RFID and special features
Schlegel also offers networking modules with support for RFID and specific I/O functions. They can be used for, for example, identification, access control, and the connection of compatible peripherals.The features available depend on the gateway and expansion module selected.
Choose the right industrial networking solution
The choice of the MBS system depends on the machine's control system, network protocol, and the number of control points. The table shows important technical choices and which communication systems Schlegel supports.
| Parameter/protocol | What you need to know |
|---|---|
| Technical choices for the MBS system | |
| Control system | PLC manufacturers, model and available communication interfaces. |
| Network protocols | Choose a base module that supports the machine's existing communication protocols. |
| Base module / gateway | Connects the MBS system to the selected industrial network. |
| Number of control points | Up to 128 control points, depending on the system configuration. |
| Expansion modules | Up to 15 modules for additional inputs and outputs. |
| RFID and special features | Check the need for RFID, analog signal handling, and specific I/O functions. |
| Power Supplies & IIoT | Check the power supply voltage, power requirement and electrical load. |
| Security features | Emergency stop and other safety functions must be designed and verified separately. |
| Industrial Ethernet | |
| PROFINET IO | Ethernet-based communication, common in Siemens-based automation systems. |
| EtherCAT | Ethernet-based protocol for fast and time-controlled communication. |
| EtherNet/IP | Industrial Ethernet, which is used, among other things, in Rockwell-based control systems. |
| POWERLINK | Ethernet-based communication system for industrial automation. |
| Field bus and other communication | |
| PROFIBUS | Fieldbus for communication between the PLC and industrial devices. |
| CANopen | CAN-based protocol for machines and control systems. |
| AS-Interface | Bus system for connecting, for example, sensors, actuators and control devices. |
| IO-Link | Point-to-point communication between IO-Link masters and compatible devices. |
Technical characteristics
- Up to 128 control points per MBS system communication system.
- Up to 15 bus-independent expansion modules
- Support for PROFINET, EtherCAT and EtherNet/IP, among others.
- Selected gateways with RFID and analog functions
Related Product Areas
FAQ – Common questions about industrial networks
What is Schlegel's MBS?
The Schlegel MBS can handle up to 128 control points. A base module can be expanded with up to 15 expansion modules. The number of available functions depends on the system configuration.
Which networks work with MBS?
The Schlegel MBS can handle up to 128 control points. A base module can be expanded with up to 15 expansion modules. The number of available functions depends on the system configuration.
Which networks work with MBS?
Schlegel offers MBS solutions for PROFINET IO, EtherCAT, EtherNet/IP, POWERLINK, PROFIBUS, CANopen, AS-Interface and IO-Link, among others. Choose the base module based on the protocol of the control system.
Can the network protocol be changed later?
Yes. The MBS is designed so that the network protocol can be changed by replacing the base module. Always ensure that expansion modules, connections, and configuration are compatible.
Can RFID be connected to MBS?
Yes. Schlegel offers dedicated gateways and expansion modules with support for RFID. The available features depend on the module and network.
Can MBS be used for emergency stop?
MBS should not be assumed to be a safety-classified emergency stop system. Security-related functions must be designed and verified separately in accordance with the machine’s risk assessment.
Need Help Finding the Right Solution?
Our product specialists will help you choose the right solution for your application. Contact us for technical advice, product selection or a quote.